Back to product
Technical Data Sheet

UV Adhesive · Code 2000

Krystal 2000

UV Adhesive

Ref
EWC/GA006/07062016
Issued
July 2016
Reviewed
Page
1

Product Description

Krystal 2000 is photo-curing UV adhesive that will polymerize under ultraviolet light (365nm) or with visible light (436nm). This fast cure adhesive will set and cure within seconds when exposed to correct UV light source and intensity. It will not turn yellow when exposed to high temperature at 80°C with good water and weather resistance. It bonds well to glass, acrylic, polycarbonate, ABS and some metals.

Characteristics

  • Excellent clarity or transparency
  • Non yellowing
  • Good thermal and shock resistance
  • Good weather resistance

Physical Properties (Uncured)

PropertiesSpecification
Chemical Properties Acrylic Resin
Appearance Clear Liquid
Viscosity @ 25°C (S14 100 rpm) 5000 - 7000
Solvent Content, % 0

Typical properties of cured material

PropertiesSpecification
Hardness, Shore D 67
Refractive Index 1.4788
Elongation @ 25°C, % 173
Glass Transition Temp, °C -16
Temperature Range °C -40 to 120

Cure Schedule

PropertiesSpecification
UV Light Intensity 1500 – 3000 mj/cm²
Wavelength 365nm
Recommended Cure Time, seconds 10 - 15

Storage Condition

Store original container in a cool and dry area where it is not exposed to high heat or direct sunlight. Advise to store UV adhesive below 25°C.

Packaging Sizes

  • 50ML Plastic Anti-UV Bottle
  • 1 Liter Plastic Anti -UV Bottle

Shelf Life

This product has 1year shelf life when stored in original, unopened container between 15-25 ºC, away from direct light sources.

Handling Precautions

Some findings indicate a lack of potential for carcinogenicity with the compositions of by long term recurrent application to the skin. However, contact with skin is likely to produce mild transient reddening. It is important to remove adhesive from skin with soap and water thoroughly. Krystal 1000 is of moderate acute toxicity by swallowing. If swallowed, induce vomiting at once and call a physician. Avoid contact with eyes. In case of contact, flush with water for at least 15 minutes and get medical attention immediately. For specific information on this product, consult the Material Safety Data Sheet.

Compliance and quality

Made under the ISO 9001 quality management system of Vitrochem Technology. RoHS declarations and Safety Data Sheets are available on request.