Technical Data Sheet
UV Adhesive · Code 1000
Krystal 1000
UV Adhesive
- Ref
- EWC/9021/07062016
- Issued
- July 2016
- Reviewed
- Page
- 1
Product Description
Krystal 1000 is a one component UV & visible light curable adhesive which is designed for bonding ABS, HIPS, PS, PC, PVC and Acrylic etc. This product is suitable for bonding applications that require high adhesion and clarity. This UV adhesive will polymerize under ultraviolet light (365nm) and cure within seconds when exposed to correct UV light source and intensity.
Characteristics
- Ultra-clear
- Good thermal and shock resistance
- Good weather resistance
Physical Properties (Uncured)
| Properties | Specification |
|---|---|
| Chemical Properties | Acrylic Resin |
| Appearance | Pale Yellow Liquid |
| Specific Gravity | 1.23 |
| Viscosity @ 25°C (S14 100 rpm) | 650 - 1050 |
| Solvent Content, % | 0 |
Typical properties of cured material
| Properties | Specification |
|---|---|
| Hardness, Shore D | 65 |
| Refractive Index | 1.4825 |
| Tensile Strength, Kg/cm² (Acrylic to Acrylic) | 108 |
| Elongation @ 25°C, % | 228 |
| Glass Transition Temp, °C | -5 |
| Temperature Range °C | -40 to 100 |
Cure Schedule
| Properties | Specification |
|---|---|
| UV Light Intensity | 1500 – 3000 mj/cm² |
| Wavelength | 365nm |
| Recommended Cure Time, seconds | 10 - 15 |
Storage Condition
Store original container in a cool and dry area where it is not exposed to high heat or direct sunlight. Advise to store UV adhesive below 25°C.
Packaging Sizes
- 50ML Plastic Anti-UV Bottle
- 1 Liter Plastic Anti -UV Bottle
Shelf Life
This product has 1year shelf life when stored in original, unopened container between 15-25 ºC, away from direct light sources.
Handling Precautions
Some findings indicate a lack of potential for carcinogenicity with the compositions of by long term recurrent application to the skin. However, contact with skin is likely to produce mild transient reddening. It is important to remove adhesive from skin with soap and water thoroughly. Krystal 1000 is of moderate acute toxicity by swallowing. If swallowed, induce vomiting at once and call a physician. Avoid contact with eyes. In case of contact, flush with water for at least 15 minutes and get medical attention immediately. For specific information on this product, consult the Material Safety Data Sheet.
Compliance and quality
Made under the ISO 9001 quality management system of Vitrochem Technology. RoHS declarations and Safety Data Sheets are available on request.